043) We also determined whether previous

bone infection,

043). We also determined whether previous

bone infection, it history, of diabetes, or smoking were risk factors for the development of complications. Diabetes, smoking, and pre-existing bone/implant infections were not significant risk factors for HTR-PMI failure. The higher rate of complications can be partially attributed to a diverse and complicated patient population, with multiple comorbid conditions and various indications for HTR-PMI reconstruction. In particular, decompressive craniectomies in trauma find more patients can be risky indications for the use of HTR-PMI.

Conclusion: Larger Studies are suggested to verify our findings. (C) 2009 American Association of Oral and Maxillofacial Surgeons”
“PURPOSE: To assess the repeatability of the anterior segment measurements performed with a dual Scheimpflug analyzer (Galilei) in unoperated and post-refractive surgery eyes.

SETTING: Private practice.

DESIGN: Evaluation of diagnostic test.

METHODS: Three consecutive scans were acquired in unoperated eyes and in eyes that had excimer laser surgery for myopia. Unoperated eyes were enrolled from 3 subgroups: younger than 50 years, aged between 50 and 70 years, and older than 70 years. The following parameters were evaluated: simulated keratometry, posterior corneal power, total corneal power, anterior and posterior

best-fit sphere radius, mean and thinnest AZD2014 mw central corneal thickness, anterior chamber depth and volume, horizontal and vertical corneal diameter, iridocorneal angle in the 4 quadrants, and corneal spherical aberration. Repeatability was assessed using analysis of variance (ANOVA), the coefficient of variation (Coy), intraclass correlation (ICC), and test-retest variability.

RESULTS: The study evaluated 45 unoperated eyes (n = 45) and 15 post-refractive surgery Selleckchem MCC 950 eyes (n = 15). Each age subgroup in the unoperated group comprised 15 eyes. The ANOVA did not detect significant differences between the 3 measurements for any parameter. The

COV was less than 0.5% for corneal power measurements and less than 3.5% for all remaining parameters except spherical aberration (16.68%). The ICC was more than 0.99 for corneal power measurements and more than 0.94 for all remaining parameters.

CONCLUSIONS: The anterior segment measurements provided by the dual Scheimpflug analyzer were highly repeatable. Repeatability did not change with age or after myopic photorefractive keratectomy or laser in situ keratomileusis.”
“The species Centaurea bruguierana (DC.) Hand.-Mazz. ssp. belangerana (DC.) Bornm. (CBB) (Asteraceae), known as “”Baad-Avard”" in Borazjan, Bushehr Province, southern Iran, is used in folk medicine as a hypoglycemic herb in diabetes and as a remedy for peptic ulcer disorders.

Comments are closed.