A high separation performance of PECSMs was achieved in the dehyd

A high separation performance of PECSMs was achieved in the dehydration of 10 wt% water-ethanol mixtures at 70 degrees C, yielding a flux and a separation

factor for the PECSM-20 at 1385 g/m(2) h and 1571, respectively. These results indicated that the introduction of free SO3 groups into PECSMs was an effective strategy to improve the pervaporation dehydration performance of PECSMs. (C) 2013 Elsevier BY. All rights reserved,”
“Functional hyperemia is the regional increase in cerebral blood flow upon increases in neuronal activity LY294002 nmr which ensures that the metabolic demands of the neurons are met. Hypertension is known to impair the hyperemic response; however, the neurovascular coupling mechanisms by which this cerebrovascular dysfunction occurs have yet to be fully elucidated. To determine whether altered cortical parenchymal arteriole function or astrocyte signaling contribute to blunted neurovascular coupling in hypertension, we measured parenchymal arteriole reactivity and vascular smooth muscle cell Ca2+ dynamics in cortical brain slices from normotensive Wistar Kyoto (WKY) and spontaneously hypertensive (SHR) rats.

We found that vasoconstriction in response to the thromboxane A(2) receptor agonist U46619 and basal vascular smooth muscle cell Ca2+ oscillation frequency were significantly increased in parenchymal arterioles from SHR. In perfused and pressurized parenchymal arterioles, myogenic tone was significantly increased in SHR. Although K+-induced parenchymal arteriole dilations were similar in WKY and SHR, metabotropic HDAC inhibitor glutamate receptor activation-induced parenchymal arteriole dilations were enhanced in SHR. Further, neuronal stimulation-evoked parenchymal arteriole dilations

were similar in SHR and WKY. Our data 3-Methyladenine in vivo indicate that neurovascular coupling is not impaired in SHR, at least at the level of the parenchymal arterioles.”
“Background: Qualitative diagnostic tests commonly produce false positive and false negative results. Smooth receiver operated characteristic (ROC) curves are used for assessing the performance of a new test against a standard test. This method, called c-statistic (concordance) has limitations. The aim of this study was to assess whether logistic regression with the odds of disease as an outcome and the test scores as covariate, can be used as an alternative approach, and to compare the performance of either of the two methods.\n\nMethods: Using as examples simulated by vascular laboratory scores we assessed the performance of logistic regression as compared to c-statistics.\n\nResults: The c-statistics produced areas under the curve (AUCs) of respectively 0.954 and 0.969 (standard errors 0.007 and 0.005), means difference 0.015 with a pooled standard error of 0.0086. This meant that the new test was not significantly different from the standard test at p=0.08.

Comments are closed.