Thus, the Young’s modulus of the sample containing 20% clay was i

Thus, the Young’s modulus of the sample containing 20% clay was increased by 193 times, while the oxygen permeability was decreased about seven times, in regard to the corresponding values of the neat polymer. The obtained results were explored on the basis of nanoscale phenomena and it was concluded that

the organized structures and intercalated regions observed on highly loaded samples are attributed to the competitive effect between weaker polymer-polymer interactions in relation to stronger polymer-clay ones. (C) 2011 Wiley Periodicals, Inc. J Appl Polym Sci 123: 1812-1821, 2012″
“Background: The emergence of Plasmodium knowlesi in humans, which is in many cases misdiagnosed by microscopy as Plasmodium malariae due to the morphological BI 10773 mouse similarity has contributed to the needs of detection and differentiation of malaria parasites. At present, nested PCR targeted on Plasmodium ssrRNA genes has been described as the most sensitive and specific method for Plasmodium detection. However, this method is costly and requires trained personnel for its implementation. Loop-mediated isothermal amplification (LAMP), a novel nucleic acid amplification method was developed for Selleck H 89 the clinical detection of P. knowlesi. The sensitivity and specificity of LAMP was evaluated in comparison to the results obtained via microscopic examination and nested PCR.

Methods: LAMP assay was developed based

on P. knowlesi genetic material targeting the apical membrane antigen-1 (AMA-1) gene. The method uses six primers that recognize eight regions of the target DNA and it amplifies DNA within an hour under isothermal conditions (65 degrees C) in a water-bath.

Results: LAMP is highly sensitive with the detection limit as low as ten copies for AMA-1. LAMP detected malaria parasites in all confirm cases (n = 13) of P. knowlesi infection

(sensitivity, 100%) and none of the negative samples (specificity, 100%) within an hour. LAMP demonstrated higher sensitivity compared Ricolinostat cost to nested PCR by successfully detecting a sample with very low parasitaemia (< 0.01%).

Conclusion: With continuous efforts in the optimization of this assay, LAMP may provide a simple and reliable test for detecting P. knowlesi malaria parasites in areas where malaria is prevalent.”
“Association mapping was used to dissect the genetic basis of drought-adaptive traits and grain yield (GY) in a collection of 189 elite durum wheat accessions evaluated in 15 environments highly different for water availability during the crop cycle (from 146 to 711 mm) and GY (from 9.9 to 67.3 q ha(-1)). For highly heritable traits (e.g. heading date, kernel weight, etc.) several significant experiment-wise marker-trait associations were detected across five or more (up to 13 for kernel weight) environments, with R-2 values ranging from ca. 5 to 10%. As to GY, significant associations (R-2 from 2.5 to 4.

Comments are closed.